Time:06-10,2010  Source:LICA UNITED  Author:fyw

The “Smart” Block Digestor for Reduced Volume Distillations

EASYDist Jr.





 

  • 10-position for reduced volume distillations or
    20 positions for acid digestions for TKN and TP

     
  • Distillation procedures include:

    •ammonia
    •cyanide
    •fluoride
    •phenol
    •sulfide, total
    •sulfide, acid-soluble
     

 

  • Digestion procedures include:

    •total Kjeldhal Nitrogen
    •total Phosphorus

Components

Heating Unit
  • Continuous heating element
  • Improved temperature uniformity
  • Improved temperature stability
  • Improved heat transfer
Smart Controller

EasyDist Controller


 

  • Large, easy to read LED display
  • Simple keypad entries to set programming parameters
  • 8 stages of temperature control
  • 8 stages of dwell times
  • Programmable rise rates for each temperature stage
  • Flash memory - no battery required
  • Digital PID (Proportional, integral, derivative) temperature control
  • Delayed start
  • End of run alarm
  • Programmable high temperature cut-off
  • Type J thermocouple
  • Built in diagnostics






     
Additional Safety Features
  • Open thermocouple detection
  • Over temperature detection by microprocessor
  • Redundant circuitry for over temperature protection
  • Independent of microprocessor and Triac

Glassware and Accessories

Distillation glassware is available for the following analytes:

  • ammonia
  • cyanide
  • fluoride
  • phenol
  • sulfide, total
  • sulfide, acid-soluble

The cyanide, fluoride, and both sulfide, a 10-position gas/vaccum distribution manifold is required. In addition, all the flexible tubing is provided as well as a comprenhensive methods manual.

Digestion

A set of 20 digestion tubes calibrated to 250 ml.

Stand

The stand holds the tubes during the digestion process, dilution, washing, and transfer. Specifically designed side plates snap onto the stand to minimize temperature fluctuatins from air drafts during digestion.

Retainer Plate

The retainer plate locks the tubes in position in the rack allowing the entire assembly to be turned upside down to facilitate cleaning. 

Specifications

Physical
  • Heating Unit 66 lbs.
  • Smart Controller 9 lbs.
Dimensions
  • Heating Unit 8½"H  x  13½"W   x  20"D
  • Smart Controller 6 ¾"H  x  6"W  x  10"D
Temperature
  • Control Range and Resolution: 50°C to 400°C in 1° increments
     
  • Accuracy: +/- 2° in control range
     
  • Amplitude at Set Point: Less than +/- 1°
     
  • Repeatability: +/- 1°
     
  • Stability: +/- 1°
  • Ramp Rate: 4°C/minute
Electrical
  • Operating Voltage: 208-240 volts, 50-60 Hz
  • Current: 12 Amps @220 volts
  • Fusing for Heating Unit: Two 15 Amp fuses @250 volts
  • Fusing for Smart Controller : Two 1 Amp fuses

 