Direct Analysis of δ2H and δ18O in Natural and Enriched Human Urine Using Laser-Based, Off-Axis Integrated Cavity Output Spectroscopy
应用LGR液态水稳定同位素分析仪测量尿液中的氢氧同位素
 
 Los Gatos Research, 67 East Evelyn Ave, Suite 3, Mountain View California 94043, United States
 Department of Ecology, Physiology and Ethology, IPHC-DEPE, Université de Strasbourg, 23 rue Becquerel 67087 Strasbourg France
§ Division of Endocrinology, Metabolism, and Diabetes/Division of Geriatrics, University of Colorado Anschutz Medical Campus, 12801 East 17th Ave, Aurora, Colorado 80045, United States
 Institute of Biological and Environmental Sciences, University of Aberdeen, Tillydrone Ave Aberdeen, AB24 2TZ, Scotland, U.K.
 State Key laboratory of Molecular and Developmental Biology, Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, Beijing, China
 
Abstract
Abstract Image
The stable isotopes of hydrogen (δ2H) and oxygen (δ18O) in human urine are measured during studies of total energy expenditure by the doubly labeled water method, measurement of total body water, and measurement of insulin resistance by glucose disposal among other applications. An ultrasensitive laser absorption spectrometer based on off-axis integrated cavity output spectroscopy was demonstrated for simple and inexpensive measurement of stable isotopes in natural isotopic abundance and isotopically enriched human urine. Preparation of urine for analysis was simple and rapid (approximately 25 samples per hour), requiring no decolorizing or distillation steps. Analysis schemes were demonstrated to address sample-to-sample memory while still allowing analysis of 45 natural or 30 enriched urine samples per day. The instrument was linear over a wide range of water isotopes (δ2H = −454 to +1702 ‰ and δ18O = −58.3 to +265 ‰). Measurements of human urine were precise to better than 0.65 ‰ 1σ for δ2H and 0.09 ‰ 1σ for δ18O for natural urines, 1.1 ‰ 1σ for δ2H and 0.13 ‰ 1σ for δ18O for low enriched urines, and 1.0 ‰ 1σ for δ2H and 0.08 ‰ 1σ for δ18O for high enriched urines. Furthermore, the accuracy of the isotope measurements of human urines was verified to better than ±0.81 ‰ in δ2H and ±0.13 ‰ in δ18O (average deviation) against three independent isotope-ratio mass spectrometry laboratories. The ability to immediately and inexpensively measure the stable isotopes of water in human urine is expected to increase the number and variety of experiments which can be undertaken.
 
 查看原文:http://pubs.acs.org/doi/pdfplus/10.1021/ac3016642
来顶一下
近回首页
返回首页
相关文章
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐文章
利用轻轨公共交通平台监测城市范围内的温室气体和污染物 (应用LGR便携式温室气体分析仪,NO2分析仪)
利用轻轨公共交通平台
应用LGR CO2同位素分析仪对幽门螺杆菌患者进行糖尿病的无创诊断
应用LGR CO2同位素分
应用ABB LGR分析仪与双标水法(Doubly-Labeled Water Method)显著地促进人体能量消耗的评估
应用ABB LGR分析仪与
中欧地区混合农业地区塔楼表面大气N2O测量的第一批结果
中欧地区混合农业地区
栏目更新
栏目热门