Rapid, Online Quantification of H2S in JP-8 Fuel Reformate Using Near-Infrared Cavity-Enhanced Laser Absorption Spectroscopy

应用LGR激光痕量气体分析仪快速在线量化JP-8(特级航空材料)中的H2S

Feng Dong†, Christian Junaedi‡, Subir Roychoudhury‡, and Manish Gupta*†

Los Gatos Research, 67 East Evelyn Avenue, Suite 3, Mountain View, California 94041, United States

Precision Combustion, Inc., 410 Sackett Point Road, North Haven, Connecticut 06473, United States

Anal. Chem., 2011, 83 (11), pp 4132–4136

DOI: 10.1021/ac200300t

Publication Date (Web): May 3, 2011

Copyright © 2011 American Chemical Society

Abstract

Abstract Image

One of the key challenges in reforming military fuels for use with fuel cells is their high sulfur content, which can poison the fuel cell anodes. Sulfur-tolerant fuel reformers can convert this sulfur into H2S and then use a desulfurizing bed to remove it prior to the fuel cell. In order to optimize and verify this desulfurization process, a gas-phase sulfur analyzer is required to measure H2S at low concentrations (<1 ppmv) in the presence of other reforming gases (e.g., 25–30% H2, 10–15% H2O, 15% CO, 5% CO2, 35–40% N2, and trace amounts of light hydrocarbons). In this work, we utilize near-infrared cavity-enhanced optical absorption spectroscopy (off-axis ICOS) to quantify H2S in a JP-8 fuel reformer product stream. The sensor provides rapid (2 s), highly precise (±0.1 ppmv) measurements of H2S in reformate gases over a wide dynamic range (0–1000 ppmv) with a low detection limit (3σ = ±0.09 ppmv in 1 s) and minimal cross-interferences from other present species. It simultaneously quantifies CO2 (±0.2%), CH4 (±150 ppmv), C2H4 (±30 ppmv), and H2O (±300 ppmv) in the reformed gas for a better characterization of the fuel reforming process. Other potential applications of this technology include measurement of coal syngas and H2S in natural gas. By including additional near-infrared, distributive feedback diode lasers, the instrument can also be extended to other reformate species, including CO and H2.

阅读原文:http://www.ncbi.nlm.nih.gov/pubmed/21486070

来顶一下
近回首页
返回首页
相关文章
    无相关信息
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐文章
利用轻轨公共交通平台监测城市范围内的温室气体和污染物 (应用LGR便携式温室气体分析仪,NO2分析仪)
利用轻轨公共交通平台
应用LGR CO2同位素分析仪对幽门螺杆菌患者进行糖尿病的无创诊断
应用LGR CO2同位素分
应用ABB LGR分析仪与双标水法(Doubly-Labeled Water Method)显著地促进人体能量消耗的评估
应用ABB LGR分析仪与
中欧地区混合农业地区塔楼表面大气N2O测量的第一批结果
中欧地区混合农业地区
栏目更新
栏目热门