应用LGR同位素分析仪测定人体尿液中的同位素丰度间的相互作用对DLW测量方法的影响

时间:2015-07-01 13:17:06  来源:Los Gatos Research  作者:Cindy  [打印版]

Inter- and intraindividual correlations of background abundances of 2H, 18O and 17O in human urine and implications for DLW measurements

科学家应用LGR同位素分析仪测定人体尿液中的2H,18O和17O丰度间的相互作用对DLW测量方法的影响

E S F Berman, E L Melanson, T Swibas, S P Snaith and J R Speakman


Background/Objectives:

The method of choice for measuring total energy expenditure in free-living individuals is the doubly labeled water (DLW) method. This experiment examined the behavior of natural background isotope abundance fluctuations within and between individuals over time to assess possible methods of accounting for variations in the background isotope abundances to potentially improve the precision of the DLW measurement.

Subjects/Methods:

In this work, we measured natural background variations in 2H, 18O and 17O in water from urine samples collected from 40 human subjects who resided in the same geographical area. Each subject provided a urine sample for 30 consecutive days. Isotopic abundances in the samples were measured using Off-Axis Integrated Cavity Output Spectroscopy.

Results:

Autocorrelation analyses demonstrated that the background isotopes in a given individual were not temporally correlated over the time scales of typical DLW studies. Using samples obtained from different individuals on the same calendar day, cross-correlation analyses demonstrated that the background variations of different individuals were not correlated in time. However, the measured ratios of the three isotopes 2H, 18O and 17O were highly correlated (R2=0.89–0.96).

Conclusions:

Although neither specific timing of DLW water studies nor intraindividual comparisons were found to be avenues for reducing the impact of background isotope abundance fluctuations on DLW studies, strong inter-isotope correlations within an individual confirm that use of a dosing ratio of 8‰:1‰ (0.6 p.p.m.:1 p.p.m.) optimizes DLW precision. Theoretical implications for the possible use of 17O measurements within a DLW study require further study. 

文章查看地址:

http://www.nature.com/ejcn/journal/vaop/ncurrent/full/ejcn201510a.html

来顶一下
近回首页
返回首页
相关文章
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐文章
利用轻轨公共交通平台监测城市范围内的温室气体和污染物 (应用LGR便携式温室气体分析仪,NO2分析仪)
利用轻轨公共交通平台
应用LGR CO2同位素分析仪对幽门螺杆菌患者进行糖尿病的无创诊断
应用LGR CO2同位素分
应用ABB LGR分析仪与双标水法(Doubly-Labeled Water Method)显著地促进人体能量消耗的评估
应用ABB LGR分析仪与
中欧地区混合农业地区塔楼表面大气N2O测量的第一批结果
中欧地区混合农业地区
栏目更新
栏目热门